CEMS Emissions Monitoring Solutions and Products

Especially in the field of analyzers and process instrumentation, fewer people must handle at least the same if not more demanding tasks. Stricter regulations and technological advances lead to higher instrument requirements. Last but not least, the going-global of the main users of process automation is forcing us as supplier to be sufficiently present and organized to meet their needs locally.

Controlling plants, meeting limits, optimizing processes, monitoring product flows – the products and customer support for analyzers and process instrumentation of SICK define standards for these tasks regarding technology and quality.

We are able to offer you:

  • Complete solutions well suited to solve your application task  low cost-of-ownership.
  • A comprehensive service package, from engineering to after-sales service.
  • Regional sales and service organizations in all major countries in the world.
  • The most modern, innovative products, characterized by their simplicity and application reliability.

CB CEMS Integrated Shelters

Description & Features

CB Engineering
Tailored for your emission monitoring requirements
CB Process can provide a complete CEMS solutions for you including the shelter, field installation management, and ongoing maintenance support.
  • Complete turnkey solutions
  • Maintenance contracts

 

SICK GM 32 In-Situ CEMS

Description & Features

Real-time gas analysis directly within the process

Innovative measurement technology that allows the devices to be mounted directly at the measurement site: In-situ gas analyzers take measurements directly within the process under system conditions. These analyzers are primarily characterized by their minimal maintenance requirements and extremely short response times. SICK’s in-situ gas analyzers are available in two different versions:

The cross-duct version for representative measurement results across the entire duct diameter
The measuring probe version, optimized for single-sided gas duct installation

At a glance

  • Direct, fast in-situ measurement
  • No gas sampling, no gas transport, no gas conditioning
  • Up to eight measuring components at the same time, plus process temperature and pressure
  • DOAS and CDE evaluation process
  • Numerous independent measuring ranges with consistent accuracy
  • Automatic self-test function (QAL3) without test gases
  • Overpressure encapsulated design for ATEX Zones 1 and 2
Your benefits
  • Measured values in real time without altering the gas composition
  • Short-term process deviations are detected
  • Representative measurement byselection of cross-duct or measuring probe versions
  • Fast on-site service due to modular design
  • Long maintenance-free intervals
  • Cost-effective in-situ gas analyzer — also in ATEX design
  • Low cost of installation and operation, no test gases required
  • Complete emissions measurement in Kraft pulp process by way of simultaneous measurement of TRS components plus SO2, NO, NH3

Do you require a different solution? Please visit the manufacturer's website for more products!
SICK Official Website

SICK DustHunter

Description & Features

SICK is setting new standards in dust measurement with its rugged and low-maintenance measuring devices for detecting and monitoring dust concentrations. All dust measuring devices are easy to integrate into existing applications – and offer straightforward installation and commissioning along with user-friendly operation.

Transmittance dust measuring devices transmit light through the entire duct. With this type of measurement, light attenuation indicates the concentration of dust inside the duct. These measuring devices are specially designed for medium to high dust concentrations and large duct diameters. Consequently, they are equally suited to emission and process monitoring as they are to hall monitoring applications.

Light scattering by dust particles is a measurement principle that allows even very low concentrations of dust to be detected. Depending on the system-specific requirements, either forward scattering or backward scattering can be used in this context. Both measurement principles return stable and reproducible measurement results, regardless of the gas velocity, humidity, or dust particle charges.

At a glance
  • From low to high dust concentrations
  • On-board contamination check
  • Automated thorough check of zero and reference point
  • For small to large measuring distances
Your Benefits
  • Easy installation, commissioning and operation
  • Measurement independent of gas velocity, humidity and particle charge
  • Low maintenance due to self-monitoring

 


Do you require a different solution? Please visit the manufacturer's website for more products!
SICK Official Website

SICK Extractive CEMS

Videos

Description & Features

8
Tailored for measuring emissions

SICK’s CEMS solutions are analyzer solutions that have been specifically designed for measuring emissions at power plants, industrial facilities, or on ships. CEMS solutions can be used to measure pollutants and reference quantities and to perform data processing on the results in accordance with the relevant national or international legislation.

At a glance
  • Extractive measurement of up to 8 IR-active gas components
  • Additional oxygen and total hydrocarbon analyzer as option
  • Gas lines heated throughout
  • Sample gas infeed on gas sampling probe or analyzer
  • Back-purging of gas sampling probe for filter cleaning
  • Rapid measured gas exchange to minimize adsorption and desorption processes
  • Automated sample point switching
Your Benefits
  • Measurement of several gas components with one analyzer
  • Heated gas paths enables measurement of difficult gases like HCl and NH3
  • Long maintenance intervals (typically 6 months) due to self monitoring of the analyzer
  • Selective measurement of NO and NO2 – no converter required
  • QAL3 drift test with internal calibration filter wheel – no test gas required

 


Do you require a different solution? Please visit the manufacturer's website for more products!
SICK Official Website

SICK Zirkor200 Combustion Oxygen Analyzer

Description & Features

At a glance
  • Measurement cell with extremely long service life due to innovative protection mechanism
  • Measurement cell self-monitoring
  • Fully automated adjustment mechanism integrated into the control unit
  • Version for high temperatures available
  • ZIRKOR remote app for remote access to analyzer
  • Very short response time
  • Suitability-tested according to EN 15267
  • Easy connection of process control systems
Your Benefits
  • Very high availability due to measurement cell with extremely long service life
  • High reliability due to innovative measurement cell protection – even in corrosive or reducing conditions
  • Reduction of analyzer failures due to internal self-monitoring
  • No manual adjustment required
  • Quick measurement close to the combustion process for timely control
  • Approved for emission monitoring
  • Easy analyzer operation – even remotely

Do you require a different solution? Please visit the manufacturer's website for more products!
SICK Official Website

Sick GHG- Control

Videos

Description & Features

Full control for companies subject to disclosure requirements.

The GHG Control (GHG = Greenhouse Gas) CEMS solution is the only in-situ solution that allows companies to monitor their greenhouse gas emissions at any time. GHG Control records CO2 and CO or N2O gas concentrations and their volume flow and correctly determines the total quantity in real time. This means that companies that are required to declare their greenhouse gas emissions always have an overview of their current CO2 and CO or N2O emissions.

 

Resources


Do you require a different solution? Please visit the manufacturer's website for more products!
SICK Official Website

SICK Flowsic100 Stack Flow

Description & Features

Volume flow measuring devices for continuous emission monitoring

At a glance

  • Rugged titanium converters for long service life
  • Corrosion-resistant material for use with aggressive gases (option)
  • Integrated measurement via duct diameter for types H, M, and S
  • Probe version PR for cost-saving, single-sided installation in duct
  • Automated operational check with zero and reference point test

Your Benefits

  • Reliable flow measurement for ducts with small up to very large diameters
  • High durability of the device
  • Minimum operating and maintenance costs
  • Accurate measuring results under difficult measuring conditions
  • Measurement without pressure loss, therefore no influences on the process
  • User-friendly operation via SOPAS ET software
  • Reliable function monitoring due to enhanced diagnosis
  • No purge air required for applications with gas temperatures up to 260 °C

Do you require a different solution? Please visit the manufacturer's website for more products!
SICK Official Website

Sick GM35 In-Situ IR Gas Analyzer

Description & Features

Simultaneous or Individual Measurement of CO2, H2O, and CO or N2O

At a glance
  • Dynamic humidity correction
  • Fast in-situ measurement directly in the process
  • Simultaneous determination of up to three gas components, temperature, and pressure
  • No gas sampling and conditioning
  • Gas testable version of measuring probe available
  • Integrated self-test and control functions
Your Benefits
  • Dynamic humidity measurement directly in the process
  • Provision of real humidity reference values
  • Unbiased measuring values due to in-situ measurement
  • Fast or short-term fluctuations in the process are being detected
  • Representative measurement by selection of an appropriate probe or cross-duct type

Do you require a different solution? Please visit the manufacturer's website for more products!
SICK Official Website

Interested in our product?

Click on the button below to complete the inquiry form and one of our Area Managers will contact you shortly
Request Info